<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Multi-Channel Strain Gage Components | RJG, Inc.</title>
	<atom:link href="https://rjginc.com/product-category/pressure-sensors/high-cavitation-es/multi-channel-strain-gage-components-es/feed/" rel="self" type="application/rss+xml" />
	<link>https://rjginc.com</link>
	<description>Award-Winning Training and Technology Company</description>
	<lastBuildDate>Thu, 03 Apr 2025 18:04:59 +0000</lastBuildDate>
	<language>es</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.2</generator>

<image>
	<url>https://es.rjginc.com/wp-content/uploads/2021/10/cropped-group@3x-100x100.png</url>
	<title>Multi-Channel Strain Gage Components | RJG, Inc.</title>
	<link>https://rjginc.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SG-8</title>
		<link>https://es.rjginc.com/product/sg-8/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:59 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/sg-8-2/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td>Max Connector Temperature</td>
<td>+85 °C/+185 °F</td>
</tr>
<tr>
<td>Number of Sensors</td>
<td>1-8</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Placa de Sensor de 8 Canales con Capacidad de Identificación</p>
<p>La placa de sensor de galga extensiométrica con capacidad de identificación del molde permite a los usuarios interconectar hasta 8 sensores de galga extensiométrica multicanal, manteniendo al mismo tiempo una huella pequeña de molde.</p>
<p><iframe title="Multi-Channel Strain Gage" width="500" height="375" src="https://www.youtube.com/embed/q-nrFSsQCFQ?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SG/LX8-S-ID</title>
		<link>https://es.rjginc.com/product/sg-lx8-s-id/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 18:38:59 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/sg-lx8-s-id-2/</guid>

					<description><![CDATA[<table class="product-specs" style="width: 100%;">
<tbody>
<tr>
<td>Channels</td>
<td>8</td>
</tr>
<tr>
<td>Accuracy</td>
<td>+/- 1%</td>
</tr>
<tr>
<td>Temp. máx</td>
<td>140 °F/60 °C</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Adaptador de Galga Extensiométrica de 8 Canales Lynx con Capacidad de Identificación</p>
<p>El adaptador de galga extensiométrica de 8 canales de Lynx proporciona a los usuarios del sensor de presión de cavidad de galga extensiométrica una interfaz simple y conveniente para los sistemas de galga extensiométrica multicanal.</p>
<p><a href="https://rjginc.com/products/607-sg-lx8-s-id-old-version-">Information on the old version of the adapter can be found here.</a></p>
<p><iframe title="Multi-Channel Strain Gage" width="500" height="375" src="https://www.youtube.com/embed/q-nrFSsQCFQ?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MCSG-125</title>
		<link>https://es.rjginc.com/product/mcsg-b-127-125/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:59 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/mcsg-b-127-125-2/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td><strong>Sensor</strong></td>
<td><strong>English</strong></td>
<td><strong>S.I.</strong></td>
</tr>
<tr>
<td>Force Range per model</td>
<td></td>
<td></td>
</tr>
<tr>
<td>MCSG-B-127-125</td>
<td>125 lb</td>
<td>.56 kN</td>
</tr>
<tr>
<td>Accuracy</td>
<td>1.25% Full Scale</td>
<td>1.25% Full Scale</td>
</tr>
<tr>
<td>Maximum Temperature - Connector</td>
<td>185 °F</td>
<td>85 °C</td>
</tr>
<tr>
<td>Maximum Temperature - Standard Sensor Head</td>
<td>250 °F</td>
<td>121 °C</td>
</tr>
<tr>
<td>Maximum Temperature - Hi-Temp Sensor Head</td>
<td>425 °F</td>
<td>218 °C</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Un sensor de presión de cavidad indirecto (bajo el pasador) con galga extensiométrica multicanal de 125 libras y un botón de ½”.</p>
<p>Las longitudes disponibles incluyen 0.2m, 0.4m, 0.6m, 0.8m, 1.2m, 1.6m y 2.0m.</p>
<p>Requisito de longitud mínima – 0,127 m (5 pulgadas)<br />
Las longitudes personalizadas están disponibles bajo pedido, no son reembolsables ni cancelables.</p>
<p>Póngase en contacto con un representante de ventas de RJG para obtener una cotización.</p>
<p>También disponible en una versión de alta temperatura, modelo: MCSG-B-127-125H.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MCSG-2000</title>
		<link>https://es.rjginc.com/product/mcsg-b-127-2000/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:59 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/mcsg-b-127-2000-2/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td><strong>Sensor</strong></td>
<td><strong>English</strong></td>
<td><strong>S.I.</strong></td>
</tr>
<tr>
<td>Force Range per model</td>
<td></td>
<td></td>
</tr>
<tr>
<td>MCSG-B-127-2000</td>
<td>2000 lb</td>
<td>8.9 kN</td>
</tr>
<tr>
<td>Accuracy</td>
<td>1.25% Full Scale</td>
<td>1.25% Full Scale</td>
</tr>
<tr>
<td>Maximum Temperature - Connector</td>
<td>185 °F</td>
<td>85 °C</td>
</tr>
<tr>
<td>Maximum Temperature - Standard Sensor Head</td>
<td>250 °F</td>
<td>121 °C</td>
</tr>
<tr>
<td>Maximum Temperature - Hi-Temp Sensor Head</td>
<td>425 °F</td>
<td>218 °C</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Un sensor de presión de cavidad indirecto (bajo el pasador) con galga extensiométrica multicanal de 2000 libras y un botón de ½”.</p>
<p>Las longitudes disponibles incluyen 0.2m, 0.4m, 0.6m, 0.8m, 1.2m, 1.6m y 2.0m.</p>
<p>Requisito de longitud mínima – 0,127 m (5 pulgadas)<br />
Las longitudes personalizadas están disponibles bajo pedido, no son reembolsables ni cancelables.</p>
<p>Póngase en contacto con un representante de ventas de RJG para obtener una cotización.</p>
<p>También disponible en una versión de alta temperatura, modelo: MCSG-B-127-2K-H.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MCSG-B-127-500</title>
		<link>https://es.rjginc.com/product/mcsg-b-127-500/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:59 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/mcsg-b-127-500-2/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td><strong>Sensor</strong></td>
<td><strong>English</strong></td>
<td><strong>S.I.</strong></td>
</tr>
<tr>
<td>Force Range per model</td>
<td></td>
<td></td>
</tr>
<tr>
<td>MCSG-B-127-500</td>
<td>500 lb</td>
<td>2.23 kN</td>
</tr>
<tr>
<td>Accuracy</td>
<td>1.25% Full Scale</td>
<td>1.25% Full Scale</td>
</tr>
<tr>
<td>Maximum Temperature - Connector</td>
<td>185 °F</td>
<td>85 °C</td>
</tr>
<tr>
<td>Maximum Temperature - Standard Sensor Head</td>
<td>250 °F</td>
<td>121 °C</td>
</tr>
<tr>
<td>Maximum Temperature - Hi-Temp Sensor Head</td>
<td>425 °F</td>
<td>218 °C</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Un sensor de presión de cavidad indirecto (bajo el pasador) con galga extensiométrica multicanal de 500 libras y un botón de ½”.</p>
<p>Las longitudes disponibles incluyen 0.2m, 0.4m, 0.6m, 0.8m, 1.2m, 1.6m y 2.0m.</p>
<p>Requisito de longitud mínima – 0,127 m (5 pulgadas)<br />
Las longitudes personalizadas están disponibles bajo pedido, no son reembolsables ni cancelables.</p>
<p>Póngase en contacto con un representante de ventas de RJG para obtener una cotización.</p>
<p>También disponible en una versión de alta temperatura, modelo: MCSG-B-127-500H.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MCSG-4000</title>
		<link>https://es.rjginc.com/product/mcsg-b-159-4000/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:57 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/mcsg-b-159-4000-2/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td><strong>Sensor</strong></td>
<td><strong>English</strong></td>
<td><strong>S.I.</strong></td>
</tr>
<tr>
<td>Force Range</td>
<td>4000 lb</td>
<td>.178 kN</td>
</tr>
<tr>
<td>Accuracy</td>
<td>2% Full Scale</td>
<td>2% Full Scale</td>
</tr>
<tr>
<td>Maximum Temperature - Connector</td>
<td>185 °F</td>
<td>85 °C</td>
</tr>
<tr>
<td>Maximum Temperature - Standard Sensor Head</td>
<td>250 °F</td>
<td>121 °C</td>
</tr>
<tr>
<td>Maximum Temperature - Hi-Temp Sensor Head</td>
<td>425 °F</td>
<td>218 °C</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Un sensor de presión de cavidad indirecto (bajo el pasador) con galga extensiométrica multicanal de 4000 libras y un botón de 5/8”.</p>
<p>Las longitudes disponibles incluyen 0.2m, 0.4m, 0.6m, 0.8m, 1.2m, 1.6m y 2.0m.</p>
<p>Requisito de longitud mínima – 0,127 m (5 pulgadas)<br />
Las longitudes personalizadas están disponibles bajo pedido, no son reembolsables ni cancelables.</p>
<p>Póngase en contacto con un representante de ventas de RJG para obtener una cotización.</p>
<p>También disponible en una versión de alta temperatura, modelo: MCSG-B-159-4K-H.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MCSG-50</title>
		<link>https://es.rjginc.com/product/mcsg-b-60-50/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 18:38:57 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/mcsg-b-60-50-2/</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td><strong>Sensor</strong></td>
<td><strong>English</strong></td>
<td><strong>S.I.</strong></td>
</tr>
<tr>
<td>Force Range per model</td>
<td></td>
<td></td>
</tr>
<tr>
<td>MCSG-B-60-50</td>
<td>50 lb</td>
<td>225 N</td>
</tr>
<tr>
<td>Maximum Temperature - Connector</td>
<td>185° F</td>
<td>85° C</td>
</tr>
<tr>
<td>Maximum Temperature - Sensor Head</td>
<td>250° F</td>
<td>120° C</td>
</tr>
<tr>
<td>Maximum Overload - All Models</td>
<td>375 lb</td>
<td>1.7 kN</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Un sensor de presión de cavidad indirecto (bajo el pasador) con galga extensiométrica multicanal de 50 libras y un botón de 6 mm.</p>
<p>Las longitudes disponibles incluyen 0.2m, 0.4m, 0.6m, 0.8m, 1.2m, 1.6m y 2.0m.</p>
<p>Requisito de longitud mínima – 0,127 m (5 pulgadas)<br />
Las longitudes personalizadas están disponibles bajo pedido, no son reembolsables ni cancelables.</p>
<p>Póngase en contacto con un representante de ventas de RJG para obtener una cotización.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MCSG-250</title>
		<link>https://es.rjginc.com/product/mcsg-b-60-250/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:57 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/?post_type=product&#038;p=11140</guid>

					<description><![CDATA[<table class="product-specs">
<tbody>
<tr>
<td><strong>Sensor</strong></td>
<td><strong>English</strong></td>
<td><strong>S.I.</strong></td>
</tr>
<tr>
<td>Force Range per model</td>
<td></td>
<td></td>
</tr>
<tr>
<td>MCSG-B-60-250</td>
<td>250 lb</td>
<td>1.1 kN</td>
</tr>
<tr>
<td>Maximum Temperature - Connector</td>
<td>185° F</td>
<td>85° C</td>
</tr>
<tr>
<td>Maximum Temperature - Sensor Head</td>
<td>250° F</td>
<td>120° C</td>
</tr>
<tr>
<td>Maximum Overload - All Models</td>
<td>375 lb</td>
<td>1.7 kN</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<p>Un sensor de presión de cavidad indirecto (bajo el pasador) con galga extensiométrica multicanal de 250 libras y un botón de 6 mm.</p>
<p>Las longitudes disponibles incluyen 0.2m, 0.4m, 0.6m, 0.8m, 1.2m, 1.6m y 2.0m.</p>
<p>Requisito de longitud mínima – 0,127 m (5 pulgadas)<br />
Las longitudes personalizadas están disponibles bajo pedido, no son reembolsables ni cancelables.</p>
<p>Póngase en contacto con un representante de ventas de RJG para obtener una cotización.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>C-SG/LX8-S</title>
		<link>https://es.rjginc.com/product/c-sg-lx8-s-xx/</link>
		
		<dc:creator><![CDATA[RJG Import]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 22:38:57 +0000</pubDate>
				<guid isPermaLink="false">https://rjginc.com/product/c-sg-lx8-s-xx-2/</guid>

					<description><![CDATA[Un cable para SG/LX8-S-ID. Las longitudes disponibles incluyen 0.5m, 1.0m, and 2.0m.]]></description>
										<content:encoded><![CDATA[<p>Un cable para SG/LX8-S-ID.</p>
<p>Las longitudes disponibles incluyen 0.5m, 1.0m, and 2.0m.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/?utm_source=w3tc&utm_medium=footer_comment&utm_campaign=free_plugin

Page Caching using Disk: Enhanced 
